RP-HPLC method for simultaneous estimation of atorvastatin calcium and ramipril from plasma.

Authors

  • VH Potdar Department of Pharmacology. Tatyasaheb Kore College of Pharmacy, Warananagar
  • VS Mule Department of Pharmacology. Tatyasaheb Kore College of Pharmacy, Warananagar
  • SA Pishawikar Department of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Morewadi
  • SD Jadhav Department of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Morewadi
  • SL Thamake Department of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Morewadi

Keywords:

Solid lipid microparticles, ketoprofen, solvent evaporation method

Abstract

Solid lipid microparticles (SLMs) loaded with ketoprofen were prepared by single emulsion-solvent evaporation method, in which glyceryl monostearate and Tween 80 were employed. The particle size was found to be 99.80±2.1μm. Microparticles observed by scanning electron microscope (SEM) showed spherical shape. The entrapment efficiency (EE %) and drug loading capacity (DL %) were found to be 72.60±1.6 % and 17.98±0.7% respectively. Results of stability evaluation showed relatively long term stability after storage at 4˚C for 3 months. The in-vivo study revealed slightly better per cent inhibition of pain i.e. 74% in comparison with 68% produced by plain drug.

Downloads

Download data is not yet available.

References

Budawari S. The Merck Index. Merck and Co. Inc.; Whitehouse Station, NJ 23rd Edn. 1996; 893:8280.

Ministry of Health and Family Welfare, Government of India. Indian Pharmacopoeia, Controller of Publication, New Delhi, 5th Edn. 2007; II: 749.

Florey K. Analytical Profiles of Drug Substances, Elsevier India Private Limited, New Delhi 2005; 10: 405-461.

Mishra P, Gupta A, Shah K. Simultaneous Estimation of Atorvastatin Calcium and Amlodipine Besylate from Tablets. Indian Journal of Pharmaceutical Sciences. 2007; 69(6): 831-833.

Jain N, Raghuwanshi R, Jain D. Development and Validation of RP-HPLC Method for Simultaneous Estimation of Atorvastatin Calcium and Fenofibrate in Tablet Dosage Forms. Indian Journal of Pharmaceutical Sciences. 2008; 70(2): 263-265.

Maheshwari KR, Sankar GG, Rao AL. HPLC Method for the Simultaneous Determination of Atorvastatin and Amlodipine in Tablet Dosage Forms. Indian Journal of Pharmaceutical Sciences. 2006; 68(2): 275-277.

Patel NM. Development and Validation of HPTLC Method for the Simultaneous Estimation of Atorvastatin Calcium and Ezetimibe. Indian Journal of Pharmaceutical Sciences. 2006; 68:793-796.

Miao XS, Metcalfe CD. Determination of Cholesterol-lowering Statin Drugs in Aqueous Samples Using Liquid Chromatography–electro Spray Ionization Tandem Mass Spectrometry. Journal of Chromatography A. 2003;998:133–141.

Bonazzi D, Cavrini V. Analysis of ACE inhibitors in Pharmaceutical Dosage Forms by Derivative UV Spectroscopy and Liquid Chromatography (HPLC). Journal of Pharmaceutical Biomedical Analysis. 1997; 6: 431-438.

Mohammadia A, Rezanour N. A stability-indicating high performance liquid chromatographic (HPLC) assay for the simultaneous determination of atorvastatin and amlodipine in commercial tablets. Journal of Chromatography B. 2007; 846: 215–221.

Zaheer Z, Farooqui MN. Stability-indicating High Performance Liquid Chromatographic Determination of Atorvastatin Calcium in Pharmaceutical Dosage Form. African Jounal of Pharmacy and Pharmacology. 2008; 2: 204-210.

Thamake SL, Jadhav SD, Pishawikar SA. Development and Validation of Method for Simultaneous Estimation of Atorvastatin Calcium and Ramipril from Capsule Dosage form by First Order Derivative Spectroscopy. Asian Journal of Research in Chemistry. 2009; 2 (1): 52-53.

Thamake SL, Jadhav SD, Pishawikar SA. RP-HPLC Method for Simultaneous Estimation of Atorvastatin Calcium and Ramipril from Capsule Dosage Form. Inventi Rapid: Pharmaceutical Analysis Quality Assurance. 2010; 1:1.

Shethi PD. Quantitative Analysis of Drugs in Pharmaceutical Formulations, CBS Publishers and Distributors, New Delhi, 3rd Edn. 1997;17.

Haitao Y, Yan F, Yiwen L. Determination of Simvastatin in human plasma by liquid chromatography–mass spectrometry. Journal of Chromatography B. 2003; 785: 369-375.

United State Food and Drug Administration. Guidance for Industry, Bio-analytical Method Validation, 2001.

Snyder LR, Kirkland JJ, Glajch JL. Practical HPLC method Development. A Wiley-Interscience Publication, 2nd Edn. 1997; 250-747.

Published

2011-06-20

How to Cite

1.
Potdar V, Mule V, Pishawikar S, Jadhav S, Thamake S. RP-HPLC method for simultaneous estimation of atorvastatin calcium and ramipril from plasma. Ars Pharm [Internet]. 2011 Jun. 20 [cited 2024 Jul. 22];52(2):14-9. Available from: https://revistaseug.ugr.es/index.php/ars/article/view/4719

Issue

Section

Original Articles