Método de cromatografía líquida de alta resolución para la determinación simultánea de fosinopril sódico e hidroclorotiazida en formulaciones de comprimidos

Autores/as

  • RC MASHRU Pharmacy Department. Center of relevance and excellence in NDDS. G.H. Patel building The M.S. University of Baroda. Kalabhavan, Vadodara
  • VB SUTARIYA Pharmacy Department. Center of relevance and excellence in NDDS. G.H. Patel building The M.S. University of Baroda. Kalabhavan, Vadodara
  • AJ THAKKER Pharmacy Department. Center of relevance and excellence in NDDS. G.H. Patel building The M.S. University of Baroda. Kalabhavan, Vadodara

Palabras clave:

Fosinopril sódico, Hidroclorotiazida, Determinación simultánea, Método HPLC

Resumen

Se ha desarrollado un método HPLC de fase inversa con detección de UV sencillo, específi co, exacto y preciso parala determinación de fosinopril sódico e hidroclorotiazida en formulaciones farmacéuticas. La solución de fármacose preparó en fase móvil y se inyectó en una columna C18 con detección de UV a 208 nm. La fase móvil era unamezcla de 0,2% p/v de ácido fosfórico en agua y acetonitrilo (30:70) añadida a una velocidad de fl ujo de 0,5 ml/mina 29 0C. Los gráfi cos de calibración fueron lineales en el rango de 10-50 μg/ml (r2 > 0,99) para el fosinopril sódicoy de 6,25-31,35 μg/ml para la hidroclorotiazida (r2 > 0,99). El límite de detección fue de 0,5 μg/ml para el fosinoprilsódico y de 1,0 μg/ml para la hidroclorotiazida, con un límite de cuantifi cación de 10 μg/ml y 6,25 μg/ml para elfosinopril sódico y la hidroclorotiazida, respectivamente. La evaluación estadística del método se examinó mediantecalibración intradía (n=5) e interdía (n=5) y resultó satisfactoria, con una exactitud y precisión elevadas. El métodosugerido se aplicó con éxito en la determinación simultánea de fosinopril sódico e hidroclorotiazida en formulacionesde comprimidos, con un elevado porcentaje de recuperación, buena exactitud y precisión.

Descargas

Los datos de descargas todavía no están disponibles.

Citas

Davis R, Coukell A, Mc Tavish D. Fosinopril. A review of its pharmacology and clinical efficacy in the management of heart failure. Drugs 1997; 54: 103-116.

Shionoiri H, Naruse M, Minamisawa K, ueda S, Himeno H, Hiroto S, Takasaki I. Fosinopril. Clinical pharmacokinetics and clinical potential. Clin Pharmacokinet 1997; 32:460-480.

Kostis JB, Garland WT, Delaney C, Norton J, Liao WC. Fosinopril: pharmacokinetics and pharmacodynamics in congestive heart failure. Clin Pharmacol Ther 1995; 58: 660-665.

Ford NF, Lasseter KC, Van Harken DR, Hammett JL, Raymond R, Manning J. Single-dose and steady-state pharmacokinetics of fosinopril and fosinoprilat in patients with hepatic impairment J Clin Pharmacol 1995; 35: 145-150.

Pizarro M, Lima MJ, Domingues J, Gouveia AC, Monteiro A, Carrageta M, de Freitas AF. Antihypertensive effect of fosinopril in mild hypertension. Rev Port Cardiol 1996; 15: 495-497.

Rosolova H, Cech J, Sefrna Effectiveness and tolerance of fosinopril in the treatment of arterial hypertension of mild and medium severity. Vnitr Lek 2001; 47: 834-839.

Wang Z, Morris KR, Chu B. Aggregation behavior of fosinopril sodium-a new angiotensin –converting enzyme inhibitor. J Pharm Sci 1995; 84: 609-613.

Karpov YA. FLAG-a program of achievability of target blood pressure levels during treatment of patients with hypertension

with fosinopril. Kardiologiia 2002; 42: 52-57.

Singhvi SM, Duchin KL, Morrison RA, Willard DA, Everett DW, Frantz M. Disposition of fosinopril sodium in healthy subjects. Br J Clin Pharmacol 1998; 25: 9-15.

Schoondyke JW, Mohan R, Kelly JL, Ponder MA, Iskandar S, Douglas JE. Fosinopril-induced hepatotoxicity in a complex medical patient. Tenn Med 2002; 95: 155-156.

Parodi A, Cozzani E, Milesi G, Drosera M, Rebora A. Fosinopril as a possible pemphigus-inducing drug. Dermatology 2002; 204: 139-141.

Pahor M, Franse LV, Deitche SR, Cushman WC, Johnson KC, Shorr RI, Kottke-Marchant K, Tracy RP, Somes GW, Applegate WB. Fosinopril versus amlodipine comparative treatments study: a randomized trial to assess effects on plasminogen activator inhibitors-1. Circulation 2002; 105: 457-461.

Angulo E, Robles NR, Grois J, Barquero A, Perez Miranda M. Comparision of the antihypertensive activity of fosinopril and irbesartan. An Med Interna 2002; 19: 571-575.

Agaev MM, Azizov VA. Efficacy of combined use of fosinopril and propanolol in acute myocardial infarction. Kardiologiia 2003; 43: 29-34.

Shinghvi SM, Dunchin KL, Morrison RA, Willard DA, Everett DW, Frantz M. Disposition of fosinopril sodium in healthy subjects. Br J Clin Pharmacol 1988;25:9-15.

Krum H, Skiba M, Gilbert RE, Comparative metabolic effects of hydrochlorthiazide and indapamide in hypertensive diabetic patients receiving ACE inhibitors therapy. Diabet Med 2003; 20: 708-712.

Cremonesi G, Cavalieri L, Cikes I, Dobovisek J, Bacchelli S, Degli Esposti D, Costa FV, Borghi C, Ambrosioni E. Fixed combination of delapril plus indapamide vs fosinopril plus hydrochlorthiazide in mild to moderate essential hypertension. Adv The 2002; 19: 129-137.

Guthire R, Reggi Dr, Plesher MM, Saini RK, Battikha JP. Efficacy and safety of fosinopril/hydrochlorthiazide combinations on ambulatory blood pressure profiles in hypertension. Am J Hypertens 1996; 9: 306-311.

Hillaert S, De Grauwe K, Van den Bossche W. Simultaneous determination of hydrochlorthiazide and several inhibitors of angiotensin-converting enzyme by capillary electrophoresis. J Chromatogr A 2001; 924: 439-349.

Paraskewas D, Demetrius G. Novel flow injection spectrophotometric determination of fosinopril using UV-assisted

digestion and an orthophosphate calibration graph. Analytica Chimica Acta 2003; 481: 321-326.

Jemal M, Huang M, Mao Y, Whigan D, Schuster A. Liquid chromatography/electrospray tandem mass spectrometry method for the quantitation of fosinoprilat in human serum using automated 96-well solid-phase extraction for sample preparation. Rapid Commun Mass Sprectom 2000; 14: 1023-1028.

Erk, N. Simultaneous determination of fosinopril and hydrochlorothiazide in pharmaceutical formulations by spectrophotometric methods. J Pharm Biomed Anal 2002; 27: 901-912.

Descargas

Publicado

2006-12-20

Cómo citar

1.
MASHRU R, SUTARIYA V, THAKKER A. Método de cromatografía líquida de alta resolución para la determinación simultánea de fosinopril sódico e hidroclorotiazida en formulaciones de comprimidos. Ars Pharm [Internet]. 20 de diciembre de 2006 [citado 20 de noviembre de 2024];47(4):375-83. Disponible en: https://revistaseug.ugr.es/index.php/ars/article/view/5039

Número

Sección

Artículos Originales