Desarrollo y validación de técnicas cromatográficas y espectrofotométricas de pares iónicos para la estimación de telmisartán e hidroclorotiazida

Autores/as

  • NM Bhatia Dept.of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Kolhapur, Maharashtra, India
  • HV Shinde Dept.of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Kolhapur, Maharashtra, India
  • MS Bhatia Dept.of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Kolhapur, Maharashtra, India
  • PB Choudhari Dept.of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Kolhapur, Maharashtra, India
  • KB Ingale Dept.of Pharmaceutical Chemistry, Bharati Vidyapeeth College of Pharmacy, Kolhapur, Maharashtra, India

Palabras clave:

hidroclorotiazida, Losartán potásico, Método de múltiples longitudes de onda, HPLC RP, Telmisartán, y Validación

Resumen

La espectrofotometría ultravioleta y pares iónicos métodos cromatográficos han sido desarrollados paraestimación simultánea de telmisartán y hydrochlrothiazide de su forma de dosificación de comprimido. El primerométodo implica múltiples longitudes de onda de estimación espectrofotométrica (Método 1) en la que la interferencia debidaa hydrochlrothiazide a 286 nm (longitud de onda para la estimación de telmisartán) fue eliminado porgrabación diferencia de absorbancia a 286 nm y 308 nm, mientras que la interferencia de telmisartán a 262 nm(Longitud de onda para la estimación de hydrochlrothiazide) se eliminó mediante el registro de la diferencia de absorbanciaa 262 nm y 282 nm. Linealidad de la respuesta fue demostrado por telmisartán en elintervalo de concentración de 5-35 mg / ml con un coeficiente de correlación cuadrado (r2) de 0,9995. Linealidad dela respuesta fue demostrado por hydrochlrothiazide en el intervalo de concentración de 3-21 mg / ml con unacoeficiente de correlación cuadrado (r2) de 0,9992. El segundo método utiliza cromatografía de par iónico(Método 2) en un HIQ sil columna ODS (250 mm de longitud x 4,6 mm de diámetro interno) usando metanol:ácido ortofosfórico 0,0025 M (70:30 en volumen pH 4,6) que contiene 0,1% de ácido sulfónico 1-hexanosal de sodio monohidratado como fase móvil con detección UV a 259 nm en un intervalo de concentración de20-120 g / ml de telmisartán y 12.5-75 mg / ml para hydrochlrothiazide. se utilizó Losartán potásicocomo patrón interno. Tanto los métodos se aplicaron con éxito para el análisis de los dos fármacosde su forma de dosificación de comprimido. Los resultados del análisis se validaron estadísticamente y según ICHQ2Bdirectrices. Los métodos desarrollados son simples, selectivas y reproducibles y pueden ser aplicados paraanálisis de rutina de las formulaciones que contienen telmisartan y hydrochlrothiazide.

Descargas

Los datos de descargas todavía no están disponibles.

Citas

Moffat AC, Osselton MD, Widdop B Clarks analysis of drug and poisons. pharmaceutical press, 3rd ed., London, p. 2004, 1602, 1109.

Palled MS et al. RP-HPLC determination of telmisartan in tablet dosage forms. Ind j phar sci 2005; 67: 108-110.

Hempen C, Gläsle-Schwarz L, Kunz U, Karst U. Determination of telmisartan in human blood plasma Part I: Immunoassay development. Anal Chim Acta 2006; 560: 35-40.

Hempen C, Gläsle-Schwarz L, Kunz U, Karst U. Determination of Telmisartan in human blood plasma Part II: Liquid chromatography-tandem mass spectrometry method development, comparison to immunoassay and pharmacokinetic study. Anal Chim Acta 2006; 560: 41-49.

Li P, Wang Y, Wang Y, Tang Y, Fawcett JP, Cui Y, Gu J. Determination of Telmisartan in human blood plasma Part II: Liquid chromatography-tandem mass spectrometry method development, comparison to immunoassay and pharmacokinetic study. J Chrom B. 2005; 828: 126-129.

Chen B, Liang Y, Wang Y, Deng F, Zhou P, Guo F, Huang L. Development and validation of liquid chromatography–mass spectrometry method for the determination of telmisartan in human plasma. Analytica Chimica Acta 2005; 540: 367-373.

Koseki N, Kawashita H, Hara H, Niina M, Tanaka M, Kawai R, Nagae Y, Masuda N.Development and validation of a method for quantitative determination of telmisartan in human plasma by liquid chromatography-tandem mass spectrometry. J Pharmaceut Biomed Anal. 2007; 43. 1769-74.

Palled MS. Difference spectrophotometric determination of telmisartan in tablet dosage forms. Indian journal of pharmaceutical sciences 2006; 68(5): 685-686.

Torrealday N, González L, Alonso RM, Jiménez RM, Lastra EO. Experimental design approach for the optimisation of a HPLC-fluorimetric method for the quantitation of the angiotensin II receptor antagonist telmisartan in urine. J Pharmaceut Biomed Anal 2003; 32: 847-857.

Daneshtalab N, Lewanczuk RZ, Jamali F. High-performance liquid chromatographic analysis of angiotensin II receptor antagonist telmisartan using a liquid extraction method. J Chrom B., 2002; 766: 345-349.

Hillaert S, De Beer TRM, De Beer JO, Bossche WV.Optimization and validation of a micellar electrokinetic chromatographic method for the analysis of several angiotensin-II-receptor antagonists. J Chrom A 2003; 984: 135-140.

Hillaret S, Bossche VD. Optimization and validation of a capillary zone electrophoretic method for the analysis of several angiotensin-II-receptor antagonists. J Chrom A 2002; 979: 323-333.

Xu M, Song J, Liang Y. Rapid determination of telmisartan in pharmaceutical preparations and serum by linear sweep polarography. J Pharmaceut Biomed Anal 2004; 34: 681-687.

British Pharmacopoeia British Pharmacopoeia commission United Kingdom, p. 1993;993, 330, 566.

Indian Pharmacopoeia Published By The Controller Of Publication, Delhi, 1996; p. 370.

The United State Pharmacopoeia. The United States Pharmacopoeial Convention Inc., 23rd ed., Rockville, 1995 p. 749.

Morra V, Davit P, Capra P, Vincenti M, Stilo AD, Botrè F. Fast gas chromatographic / mass spectrometric determination of diuretics & masking agents in human urine development and validation of a protective screening protocol for antidoping analysis. J Chrom A 2006; 1135: 219-229.

Razak AO. Electrochemical study of hydrochlorothiazide & its determination in urine & tablets. J Pharmaceut Biomed Anal 2004; 34: 433-440.

Pulgarín JM, Molina AA, Nieto GP. Determination of hydrochlorothiazide in pharmaceutical preparations by time resolved chemiluminescence. Anal Chim Acta 2004;18: 37-43.

Luis M, Corujedo S, Blanco D, Jimenze A, Jimenze A, Arias JJ. Micellar electrokinetic capillary chromatography analysis of diuretics in pharmaceutical formulations. Talanta 2002; 57: 223-231.

Niopas I, Daftsios AC. A validated HPLC method for the determination of hydrochlorothiazide in human plasma & its application in pharmacokinetic studies J Liq Chrom Relat Tech 2000; 25: 487-497.

Patel LJ, Suhagia BN, Shah PB, Shah RR. Simultaneous estimation of bisoprolol fumarate and hydrochlorothiazide in tablet dosage form by RP-HPLC method. Indian Journal of Pharmaceutical Sciences, 2006;8(5): 635-638.

Pawar S. et al. Simultaneous determination of related compound and degradants of lisonopril and hydrochlorothiazide in lisonopril and hydrochlorothiazide using a stability indicating reverse phase high performance liquid chromatography. Indian Drugs 2006; 43(5): 429-432.

Sahu R, Vandana PB. Simultaneous spectrophotometric determination of ramipril and hydrochlorothiazide from their binary mixture by simultaneous equation method. Indian Drugs 2006; 43(3): 226-230.

Shankar MB, Mehata FA, Bhatt KK, Mehata RS, Geetha M. Simultaneous spectrophotometric determination of losartan potassium and hydrochlorothiazide in tablet. Indian Journal of Pharmaceutical Sciences 2003; 65(2): 167-170.

Wankhede SB, Tajne MR, Gupta KR, Wadodka SG. RP-HPLC method for simultaneous estimation of telmisartan and hydrochlorothiazide in tablet dosage form. Ind J. Pharm. Sci 2007; 69(2): 298-300.

Shah NJ, Suhagia BN, Shah RR, Shah PB. Development and validation of a HPTLC method for the simultaneous estimation of telmisartan and hydrochlorothiazide in tablet dosage form. Ind J. Pharm. Sci 2007; 69(2): 202-205.

Descargas

Publicado

2010-09-20

Cómo citar

1.
Bhatia N, Shinde H, Bhatia M, Choudhari P, Ingale K. Desarrollo y validación de técnicas cromatográficas y espectrofotométricas de pares iónicos para la estimación de telmisartán e hidroclorotiazida. Ars Pharm [Internet]. 20 de septiembre de 2010 [citado 22 de diciembre de 2024];51(3):145-54. Disponible en: https://revistaseug.ugr.es/index.php/ars/article/view/4870

Número

Sección

Artículos Originales